Input voltage of cigarette machine baking igniter


Release time:

2022-11-28

The high-voltage ignition needle cannot be grounded, otherwise it will ring to the service life of the high-voltage electromagnetic coil of the gas stove igniter. The sensor pin will cause poor magnetic induction and he will alarm and terminate the operation. The high-pressure arcing spacing of the ignition needle should be 3-6MM, not too wide, otherwise it is very easy to cause non-ignition during use, and it is very easy to burn the cigarette machine baking igniter.

The input voltages of the cigarette machine baking igniter are 1.5V, 4.5V, 12V and 220V, which can also be customized according to customer requirements.

The reason why the natural gas water heater does not burn is the problem of switching power supply, common faults of magnetic valve, common faults of igniter, magnetic induction magnetic needle problem, pressure problem, natural gas problem and exhaust pipe problem. The treatment method is judged according to the actual situation.

Natural gas water heater, also known as gas water heater, is a kind of gas appliance with natural gas as the material, according to the ignition heating method, the heat transfer process to the cold water through the heat exchanger, so as to achieve the purpose of preparing boiling water.

The problem of switching power supply is to check whether the display light of the AC power cord plug is on. The solution is to change the battery.

Magnetic valve common fault relay damage or aging, solution: relay aging is to replace the solenoid valve.

Common faults of cigarette machine baking igniter The igniter does not ignite. The treatment method is to replace the pulse igniter and the control panel.

Common Faults of Magnetic Induction Needle Ignition Needle Deviation or Difficulty in Ignition during Aging or Senescence of Human Body Induction Lamp. Treatment: Disassemble and replace the ignition needle or place it properly; The magnetic induction can be lit and placed.

The pressure problem may be that the filter screen is blocked. The solution is to replace the filter screen or habitually clean it.

Natural gas may be due to the blockage of the safety channel of natural gas source. The treatment method is to pass through the safety channel.

The problem of exhaust pipe may be that the exhaust pipe is too long or part of it causes blockage. The treatment method is: if the exhaust pipe is too long, you can choose to replace it with a shorter one. If the middle part causes blockage, it can be removed frequently.

The basic principle of the natural gas water heater is that cold water enters the electric water heater, pushes the water-gas linkage valve through the water-gas linkage valve body under the influence of a certain working pressure error of the flowing water, and promotes the DC regulated power supply to toggle the switch switch to connect and run the pulse igniter. In addition, open the high-pressure solenoid valve of the natural gas gathering station, and re-ignite automatically according to the pulse igniter until the ignition is successful to normal operation state, this link lasts for about 5~10 seconds.

Gas stove repair near the door. (gas stove repair) gas stove igniter has been discharged how to do? (gas stove repair) gas stove igniter has been discharged what is the reason and solution? 3, the switch contact is broken, can not open, adjust the position of the thermocouple, so that the fire temperature can affect its normal use;